2000 48v Club Car Regen 2 Dead
My 2000 48v club car Regen 2 sepex can't get it to move tried all Sergio's recommendations except for the testing of the controller and the motor. I have new batteries and cables , I have voltage everywhere tested ky switch Fnr switch I have the vglide throttle micro switch test ok. New solenoid .. Did the OBC Bypass .I have no ground from controller to solenoid even I give the ground to the solenoid cart won't move , and no reverse buzzer ever ! Please help!
|
Today | |
Sponsored Links
__________________
This advertising will not be shown in this way to registered members. Register your free account today and become a member on Buggies Gone Wild Golf Cart Forum |
|
07-23-2015, 06:27 PM | #2 |
Happy Carting
Join Date: Dec 2007
Location: Southern California
Posts: 73,358
|
Re: 2000 48v Club Car Regen 2 Dead
I'm sorry to hear this - does the solenoid click when you try to go?
If no Did you jump the solenoid high amperage terminals and try to run? |
07-23-2015, 06:40 PM | #3 |
Not Yet Wild
Join Date: Jun 2011
Posts: 56
|
Re: 2000 48v Club Car Regen 2 Dead
No no Click on solenoid...Solenoid does not click ,as it never gets a ground.it will click if I give it ground and I get pack voltage across solenoid big lugs when I give ground ..
|
07-23-2015, 06:41 PM | #4 |
Not Yet Wild
Join Date: Jun 2011
Posts: 56
|
Re: 2000 48v Club Car Regen 2 Dead
Will try it !
|
07-23-2015, 06:56 PM | #5 |
Happy Carting
Join Date: Dec 2007
Location: Southern California
Posts: 73,358
|
Re: 2000 48v Club Car Regen 2 Dead
So what's the problem, run with a negative jumper wire on the solenoid. Doe it charge?
|
07-23-2015, 07:00 PM | #6 |
Not Yet Wild
Join Date: Jun 2011
Posts: 56
|
Re: 2000 48v Club Car Regen 2 Dead
No ......jumping large lugs on solenoid didn't work .
I've tried to find how to test a Regen 2 motor and controller but only found Regen 1 test probably same for motor but controller is different , is there a sticky for Regen 2 controller test? |
07-23-2015, 07:05 PM | #7 |
Not Yet Wild
Join Date: Jun 2011
Posts: 56
|
Re: 2000 48v Club Car Regen 2 Dead
No cart won't do anything ,even when I bypassed , All I can , jumped out solenoid, OBC bypass.. Won't move ,it won't even twitch ..it's not listening To throttle or controller has no power no back up alarm I have new batts and wires too ..stumped
|
07-23-2015, 07:08 PM | #8 |
Not Yet Wild
Join Date: Jun 2011
Posts: 56
|
Re: 2000 48v Club Car Regen 2 Dead
Cart will not respond to to working charger, does not charge.. we have 2club cars and 2chargers this is the only Regen I have messed with.. charger charges other carts but not this one!
|
07-23-2015, 07:17 PM | #9 |
Happy Carting
Join Date: Dec 2007
Location: Southern California
Posts: 73,358
|
Re: 2000 48v Club Car Regen 2 Dead
*** regen 2. Light it up.
Basically for a controller test you have verify all the inputs are correct and check for output. |
07-23-2015, 08:11 PM | #10 |
Not Yet Wild
Join Date: Jun 2011
Posts: 56
|
Re: 2000 48v Club Car Regen 2 Dead
Wish I could light it up! Has Sergio been on? Heard revolution was going to have some conversions but didn't see any on his site. Any info on doing away with the OBC ? I know they were for fleet maintenance but does the chargers or the Obc controll the rate of charge..
|
|
Thread Tools | |
Display Modes | |
|
Similar Threads | ||||
Thread | Forum | |||
2000 Club Car DS Regen 48v problems | Electric Club Car | |||
2000 club car ds regen 2 not moving | Electric Club Car | |||
2000 Club Car Regen question | Extreme DC! | |||
2000 Electric Club Car regen brake | Electric Club Car | |||
1998 Club Car Regen//Dead End! | Electric Club Car |