Electric Club Car Electric DS, and Precedent golf cars |
|
Thread Tools | Display Modes |
08-02-2010, 10:11 PM | #1 |
Gone Wild
Join Date: Nov 2008
Location: Peachtree City, Georgia
Posts: 1,546
|
My Turn.... now mine won't run.
After fixing everyone else's cart all the time mine now has problems.
Specs; 2001 Regen, AllTrax DCX500PDPlus, Admiral motor, f/r toggle switch. Situation: Runs in reverse will not go in forward, does not even try. Solenoid clicks though. 1. Checked Toggle switch for continuity, good. 2. Press throttle, solenoid clicks, no movement of tires, DCX throws 5 flashing red error codes, indicating an open. 3. For grins swap the s1 and s2 leads, no change, put wires back to normal. 4. Continuity test of motor, pulled wires off. A1-A2 continuity, S1-S2 Continuity, no continuity between any of the four and the case. No continuity between A1 and S2, slight continuity between A2 and S1. Check again and no continuity... Hmmm 5. Wire motor right to pack, short S1 to A2. Take A1 to -negative, S2 to positive on only 3 batteries, motor runs backwords, reverse connections at battery, motor still runs backwords. Then take S2 and wire to A1 and repeat test, motor runs backwards, swap at the battery and get sparks like a dead short. 6. Pull motor, take apart clean out, nothing obvious, put back together, no shorts, all continuity tests check ok. Install motor. 7. Same symptons. Runs in reverse but not forward. Any ideas? |
Today | |
Sponsored Links
__________________
This advertising will not be shown in this way to registered members. Register your free account today and become a member on Buggies Gone Wild Golf Cart Forum |
|
08-02-2010, 10:45 PM | #2 |
The Last Moja Morani
Join Date: Jan 2007
Location: jumping from cart to cart
Posts: 8,975
|
Re: My Turn.... no mine won't run.
more than likely you have but in case have you checked the micros in the F&R switch? also by the way those switches do go bad i learned that the hard way after over looking it for hours .............but since you have reverse and i,m just guessing the problem should be in the F&R or the micros.....tucked in there.........i think there are 3 of them stacked one against the other.......................................
|
08-02-2010, 10:52 PM | #3 |
Gone Wild
Join Date: Nov 2008
Location: Peachtree City, Georgia
Posts: 1,546
|
Re: My Turn.... now mine won't run.
No, there are no micros, this is the toggle switch, on a regen 2 cart with MCOR, everything is done in the controller. There is 1 three wire toggle switch. If the switch is in neutral there is no power to the controller as it should be; put in forward and the controller comes on as it should so not an F/R problem.
I think think this is a motor issue but not sure, one thing for sure is the DCX is seeing an open towards the motor or within the controller itself. |
08-02-2010, 11:03 PM | #4 |
The Last Moja Morani
Join Date: Jan 2007
Location: jumping from cart to cart
Posts: 8,975
|
Re: My Turn.... now mine won't run.
its quite odd to see a motor go bad that way in just one direction.........but stranger things have happened.............this might be one for the gurus whenever they read it..........................................
|
08-03-2010, 06:22 AM | #5 |
Gone Wild
Join Date: Nov 2008
Location: Peachtree City, Georgia
Posts: 1,546
|
Re: My Turn.... now mine won't run.
For giggles I replaced the PDPlus adapter on the controller with a new one, hoping for an easy fix, I was denied. Same problems, I am thinking it's either motor or controller.
|
08-03-2010, 08:23 AM | #6 |
The Last Moja Morani
Join Date: Jan 2007
Location: jumping from cart to cart
Posts: 8,975
|
Re: My Turn.... now mine won't run.
my guess is controller but its just a guess....................................
|
08-03-2010, 08:24 AM | #7 |
Gone Wild
Join Date: Nov 2008
Location: Peachtree City, Georgia
Posts: 1,546
|
Re: My Turn.... now mine won't run.
Looks like I tested my motor wrong, I wired it for a series instead of a Shunt, so when I get home I will test again with low voltage. I should have tied S1 to A1 and the S2 to A2. Take 12V positive and hook to the S1/A1 combination and 12V negative goes to the S2/A2 combination. I wired before for a series... i.e. S1 to A2... then A1 to pack and S2 to pack. So will test again. |
08-03-2010, 08:26 AM | #8 |
The Last Moja Morani
Join Date: Jan 2007
Location: jumping from cart to cart
Posts: 8,975
|
Re: My Turn.... now mine won't run.
i was just gonna post what rabbit told another member i,m thinkin you read the same thing?............................................ .
|
08-03-2010, 08:34 AM | #9 |
Gone Wild
Join Date: Nov 2008
Location: Peachtree City, Georgia
Posts: 1,546
|
Re: My Turn.... now mine won't run.
No but essentially what Rabbit referred to is the same thing I already did but that was for a series motor, for the shunt motor the fields are in parallel so trying to do a test that way won't work. I have to tie A1 and S1 together and A2 and S2 together and then apply voltage to the A1/S1 combo and the A2/S2 combo since their in parallel not series.
|
08-03-2010, 10:13 AM | #10 |
let it SNOW
Join Date: Apr 2009
Location: Marengo OHIO
Posts: 871
|
Re: My Turn.... now mine won't run.
sounds like a motor problem to me
test the output on the controller while in foreward to see if anything is going to the motor then try the motor test like you have it in your last post |
|
|