Charger will not shutoff
I have searched quite a few threads on the site with the same subject as this thread and am led to think that I either have an OBC issue or my pack is too old. Was hoping someone with more experience could sanity check my thinking.
This is an 02 Club Car, series motor. The batteries will be 4 years old come January. The cart is used for trips under 10 miles and this pack has been just fine for that. Recently, my charger would not automatically shut off. NOTE: I have not verified whether it shuts off at the 16 hour mark. I will know this in a few hours. It seems to stay on about 3 amps "forever", even if the pack was hardly used. This has happened with TWO different chargers, both known good. As I wait to see if it shuts off at 16 hours, I wanted to share the pack voltage. The charger has been on since 6 PM last night, it is at 3-4 amps and the pack is at: 57.2 - 9.70, 9.27, 9.67, 9.70, 9.38, 9.50 Is there anything else to check at this point of the charge cycle? Granted this pack is aging, but are those numbers so low that it prevents charger shut off? I have s second '02 CC. I could switch the OBCs as a test if folks think it could be the OBC. I appreciate any thoughts, Thanks Alan Last edited by ajbrown; 12-05-2011 at 07:49 AM.. Reason: Added two charger comment |
Today | |
Sponsored Links
__________________
This advertising will not be shown in this way to registered members. Register your free account today and become a member on Buggies Gone Wild Golf Cart Forum |
|
12-05-2011, 08:16 AM | #2 |
Happy Carting
Join Date: Dec 2007
Location: Southern California
Posts: 73,408
|
Re: Charger will not shutoff
Yes, those numbers are way too low to shut the charger off. It is looking for about 63v. Ask Santa for some new batteries
|
12-05-2011, 08:30 AM | #3 |
The Last Moja Morani
Join Date: Jan 2007
Location: jumping from cart to cart
Posts: 8,975
|
Re: Charger will not shutoff
try letting it go the entire 16 hours than check voltage again......they will sit at 3 amps or so for a long time...............my batteries are brand new maybe 10 charges and 2 different chargers still sit under 5 amps for some time............................
|
12-05-2011, 08:31 AM | #4 |
Happy Carting
Join Date: Dec 2007
Location: Southern California
Posts: 73,408
|
Re: Charger will not shutoff
New batteries and old batteries charge then longest times
|
12-05-2011, 08:39 AM | #5 |
The Last Moja Morani
Join Date: Jan 2007
Location: jumping from cart to cart
Posts: 8,975
|
Re: Charger will not shutoff
|
12-05-2011, 08:51 AM | #6 | |
Getting Wild
Join Date: Dec 2009
Location: The Villages, FL
Posts: 144
|
Re: Charger will not shutoff
Quote:
On-Charge Voltage Test"The on-charge voltage for the set should read between 56 and 63 volts" Alan comment: This would indicate 56V is the low number?? Battery Troubleshooting Chart "Reading below 6 amps and on-charge set voltage above 56V" and then the next test is to look for a bad battery: "Any reading below 9.3 and not within .7 volts of batteries above 9.3" Alan comment: I do have one at 9.27, but it is within .7 Next would be a hydrometer test accoring to manual, but I am more interested in what value the OBC (I assume OBC) is looking for to call the pack charged.... Like I said, I am just trying to learn from the experience for future packs and I appreciate the help. Thanks |
|
12-05-2011, 08:59 AM | #7 |
Happy Carting
Join Date: Dec 2007
Location: Southern California
Posts: 73,408
|
Re: Charger will not shutoff
I think the official # is 58.3v but as I stated every CC I have ever checked ( maybe 10-12) Have gone to 63v and shut off. If you wish to further test your batteries, shut the charger off and let them sit for 12hours. Test & record voltage and SG for each cell. Post the results here if you want me to look at them.
|
12-05-2011, 09:04 AM | #8 | |
Getting Wild
Join Date: Dec 2009
Location: The Villages, FL
Posts: 144
|
Re: Charger will not shutoff
Quote:
I do not need to further test batteries, this was trying to understand some facts about why the OBC would not shut off charger. Thanks again, Alan |
|
12-05-2011, 09:41 AM | #9 |
Gone Wild
Join Date: Oct 2010
Location: Panama City, FL
Posts: 1,408
|
Re: Charger will not shutoff
with the charger on, what is the mains voltage at the outlet?
|
12-05-2011, 10:01 AM | #10 |
Getting Wild
Join Date: Dec 2009
Location: The Villages, FL
Posts: 144
|
Re: Charger will not shutoff
|
|
|
Similar Threads | ||||
Thread | Forum | |||
Timer charger - any way to mod for auto shutoff? | Electric EZGO | |||
new batts and charger wont charge, charger works on other carts | Electric Club Car | |||
How to hook up 12volt charger with 36 volt charger to charge 48 volts | Electric EZGO | |||
Textron Charger Auto-Shutoff | Electric EZGO | |||
converting an old style dial charger to a smart charger for Marathon | Electric EZGO |