Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV. |
|
Thread Tools | Display Modes |
05-30-2016, 10:41 AM | #1 |
Not Yet Wild
Join Date: May 2016
Posts: 6
|
Troubleshooting 1999 Ezgo txt
I have a 1999 Ezgo txt with series drive. The cart just quit moving. I tested the reed switch and that was not the problem. The solenoid clicks when the accelerator is pressed. So I do not think that is the problem. I visually inspected the f/r switch and think I'm good there. I was then doing a high amperage circuit testing. I have no pack load on the voltmeter when I test the controller at the B- and M- post. So then I moved the red lead to all of the other terminals and I have no pack load on the A1 and A2 terminals on the motor and no load on the A terminal on the F/R switch. I believe my problem maybe somewhere in this area. Can anyone offer some direction on how to correct this problem. Thanks.
|