02-23-2019, 05:16 PM | #1 |
Not Yet Wild
Join Date: Feb 2019
Location: SE Virginia
Posts: 12
|
New ALLTRAX XTC 48500 PDS controller Error code
2007 EZGO TXT PDS 36 volt
ALLTRAX XCT 48500 pds controller with fan from carts unlimited Heavy duty solenoid oredered with controller from carts unlimited July 2018 Trojan T605. 6 volt batteries Stock dashboard FnR switch Lifted 22"-11-10 nobby tires Rear flip seat Stock motor- Advanced DC AU2500. (7/17/06) New 2 gauge wire all around, even to the motor. Each battery has tested to 6.2 volt. Altogether = 37.8 volts I bought this cart and ran it a few weeks until the controller failed. After doing a bunch of reading and research I purchased through carts unlimited a ALLTRAX 48500 pds controller with my intention to upgrade my motor at a later time (basically when $ allows) I installed and connected my computer and decreased the amps to 400 and set. I reduced the max rpm to 2800 as per motor specs and set. I tweeted the throttle adjustment a bit for slower controlled starts and set. I tested with computer attached with rear on jack stands I did not get any codes or any signs of issues. After dropping to the ground and doing a live test, I pressed tho pedal and heard a small pop and the diode between the BIG solenoid posts popped. I'm fairly certain I had the diode in correct direction. Stripe to positive battery. Now I'm getting 1 green 3 red code for battery over voltage. What do I need to do to correct this issue. I guess I'll go get a new diode for solenoid first. |
Today | |
Sponsored Links
__________________
This advertising will not be shown in this way to registered members. Register your free account today and become a member on Buggies Gone Wild Golf Cart Forum |
|
02-23-2019, 05:55 PM | #2 |
Gone Wild
Join Date: Feb 2019
Location: North Florida
Posts: 271
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
I believe the component that gets installed on the high voltage terminals is a resistor which is not directional. The component installed on the small terminals is a diode and is directional. The marked side goes on the positive post.
|
02-23-2019, 06:07 PM | #3 |
Gone Mad
Join Date: Oct 2009
Location: Buford, GA
Posts: 8,988
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
I looked up Alltrax XCT - someone had XTC on their mind - wiring diagram, and it appears to require a regen diode across the large terminals. I would double check the diode stripe is on pack positive, unless it 'sploded too much to tell.
|
02-23-2019, 06:49 PM | #4 |
Not Yet Wild
Join Date: Feb 2019
Location: SE Virginia
Posts: 12
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
Ooopps , My bad on the XCT, my dislexia crisscrosses things like that. And yep it's done and popped the diode
|
02-23-2019, 06:51 PM | #5 |
Gone Mad
Join Date: Oct 2009
Location: Buford, GA
Posts: 8,988
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
Bad joke on my part. I only mentioned it as it's a "fun" drug.
|
02-23-2019, 07:16 PM | #6 |
Techno-Nerd
Join Date: Jun 2011
Location: West Virginia
Posts: 19,654
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
You are providing information for a series drive and the thread is about a sepex drive, which does not have a pre-charge resistor and when when an XCT controller is installed, two diodes are used.
|
02-23-2019, 07:55 PM | #7 |
Techno-Nerd
Join Date: Jun 2011
Location: West Virginia
Posts: 19,654
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
The banded end of regen diode that is installed between the solenoid's large terminals should face the battery side large terminal, the one with the cable that is connected to the main positive terminal on the battery pack.
If installed backwards, there is the possibility it might pop when the pedal is pushed since solenoid contacts bounce a few times before they stay closed and while they are bouncing, the 6A diode would be trying to pass a couple hundred amps. When installed correctly, the regen diode opposes the amp flow from the battery pack to the motor (via the controller) and passes amps from the motor to the battery pack, aka Regen Braking. The purpose of the regen diode is to protect the XCT controller from being hit with abnormally high voltage if the solenoid contacts open during regen braking, which is an unlikely event, but something in the solenoid activation circuit could fail at a most inopportune moment in time and take out the controller when only an external wire failed. The diode connects the positive voltage from the motor to the battery pack and keeps it down to whatever the battery pack voltage is instead of letting it skyrocket like what happens to the output voltage of a rapidly spinning generator without a load. ----------- The regen diode is strictly a protective device and is not needed to operate cart, so something else is wrong. The 1-3 error code indicates the battery pack voltage is higher the the over voltage slider is set for. Cut and Paste form XCT manual: Battery Over Voltage: B+ Voltage Higher than Over Voltage Battery Setting. Check pack voltage or program settings ---------- While checking that, you can also up the RPM limit setting to 6000RPM A stock PDS controller limited motor to 4400RPM in the freedom mode and with a 36V battery pack the max the motor will turn (with stock height tires) is about 5600RPM. With your 22" tall tires and rear seat, you have little danger of over-revving the stock motor. |
02-24-2019, 11:16 AM | #8 |
Not Yet Wild
Join Date: Feb 2019
Location: SE Virginia
Posts: 12
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
Thanks Jonny. I will try all of this. I found I had the original regent diode backwards. On my paperwork with new HD solenoid there is one direction that says a 250ohm resistor is used for 36 volt. I'm going to steal the one of my old solenoid. ( it has 250ohm printed on it) Hope I don't screw anthing up by doing this.
|
02-24-2019, 11:48 AM | #9 |
Not Yet Wild
Join Date: Feb 2019
Location: SE Virginia
Posts: 12
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
Tested successfully, and first ride went perfect. Thanks!!!!
|
02-24-2019, 11:52 AM | #10 | |
Techno-Nerd
Join Date: Jun 2011
Location: West Virginia
Posts: 19,654
|
Re: New ALLTRAX XTC 48500 PDS controller Error code
Quote:
I'd contact Alltrax before installing the resistor for your old solenoid. |
|
|
|
Similar Threads | ||||
Thread | Forum | |||
Alltrax XTC 500 Error Code | Electric EZGO | |||
alltrax error code high throttle input underrange | Electric Club Car | |||
06 TXT PDS 36v- Alltrax error code question | Electric EZGO | |||
Alltrax SPM-48500 Motor Controller no increased performance | Electric EZGO | |||
Alltrax SPM 48500 error code | Electric EZGO |