I have just finished installing an Alltrax 48400 SR controller, 400amp solenoid, and HD SW202 F&R switch. I now do not have any power at the key switch. The cart is a 36V, 2007 series TXT. Below are some pics to show the current state.
When I put the key in and switched it on there was nothing. No activity at the pedal, and my USB charger that displays voltage that is connected to my 12-volt reducer does not come on. I have checked and rechecked wiring and I cannot find the problem. Are there some checks I can go through to try and isolate the issue? Appreciate all the experts here and looking forward to getting my buggy up and running! |
Today | |
Sponsored Links
__________________
This advertising will not be shown in this way to registered members. Register your free account today and become a member on Buggies Gone Wild Golf Cart Forum |
|
10-14-2019, 09:33 PM | #2 |
Gone Wild
Join Date: Sep 2012
Location: Charlotte, NC
Posts: 9,329
|
Re: No Power When Key Switch Turned On
The cable #3 (top left on your picture) is on the wrong post.
Also, that wiring diagram is wrong, cables #3 and #4 need to be swapped around. Keep copper to copper connections, the washers go on top of the cable terminals. There is s nut missing in your reversing contactor picture. |
10-14-2019, 09:37 PM | #3 |
Not Yet Wild
Join Date: Dec 2017
Posts: 8
|
Re: No Power When Key Switch Turned On
I have a similar issue going right now. I am reading 4.2V on the voltmeter installed on the cart. When I insert the key and try to go forward or reverse, the voltmeter drops to nothing and the cart does not move.
Charger works like a champ. Lights turn on as expected. Handheld Voltmeter read appropriate voltage at battery terminals. NOTE: my wiring on the solenoid is mirrored yours. You connect the plus to the side I read as the negative and vice versus. I just upgrade my 98 Ezgo with the a SR48400 and 400a Solenoid. |
10-14-2019, 10:11 PM | #4 | |
Not Yet Wild
Join Date: Jun 2016
Location: D/FW
Posts: 20
|
Re: No Power When Key Switch Turned On
Quote:
Still no power at the key switch. |
|
10-14-2019, 11:49 PM | #5 |
Gone Wild
Join Date: Sep 2016
Location: Northern California
Posts: 1,300
|
Re: No Power When Key Switch Turned On
Did you get this stuff from Scotty? That install sheet is not his, which has a note about connecting a couple of wires that weren’t originally together. I think it was blue and red, but I’ll have to dig up the diagram to recall. I did mine too long ago to remember without the sheet. Whatever it was, if you didn’t do it, it resulted in what you have now.
Sergio is an electrical genius, so he’ll most likely straighten you out. |
10-14-2019, 11:53 PM | #6 |
Gone Wild
Join Date: Sep 2016
Location: Northern California
Posts: 1,300
|
Re: No Power When Key Switch Turned On
Just looked at your posted diagram and red wire comes from your charger interlock. That’s where it all starts. I think that used to go to one of the micro switches. You have to connect that to the blue wire that brings voltage to the key switch. I see in your other pic that you have them connected, but something is wrong if you have nothing at the switch. Trace it from the interlock.
|
10-15-2019, 05:57 AM | #7 |
Gone Wild
Join Date: Sep 2012
Location: Charlotte, NC
Posts: 9,329
|
Re: No Power When Key Switch Turned On
Put a meter on that wire cap (blue and red wires) and check for voltage, if 0v the reed switch in the charger receptacle is bad.
Make sure no cable is placed on that top left post on your reversing contactor picture. Fix all the other multi-connector places: Pack negative battery post should have main cable first then the other small ring connectors.The Controller connectors are designed to have the cables connected on top of the tabs where you can verify a flat connection and not stress the tab with the turning bolt head. |
10-15-2019, 08:41 AM | #8 | |
Not Yet Wild
Join Date: Jun 2016
Location: D/FW
Posts: 20
|
Re: No Power When Key Switch Turned On
Quote:
1. When you say "Make sure no cable is placed on that top left post on your reversing contactor picture." That cable needs to drop down to the post directly below it correct? 2. On pack positive, when you refer to the main cable are you referring to the cable from the solenoid or the cable from the charging receptacle? Thanks! |
|
10-15-2019, 11:36 AM | #9 | |
Gone Wild
Join Date: Sep 2012
Location: Charlotte, NC
Posts: 9,329
|
Re: No Power When Key Switch Turned On
Quote:
Since Your Reversing Contactor has magnetic blowouts, evident by the + symbol printed near the two top posts connected by the straight copper bar, it is imperative the highest voltage potential cable connection goes there. You need to run the cable from the Controller B+ to those two posts connected with the straight bar. The cable from Motor A2 post goes to the bottom connector on the same side as the two posts connected with the straight bar, which is indicated as #3 on your diagram. That bottom terminal can be on either side of the Contactor and Yours is on the opposite side as the drawing. The purpose of a wire connection is to efficiently transfer current so You always place the cable with the most current carrying capacity in direct contact with the surface of the terminal: Battery post, Solenoid Post, Controller terminal or fuse. Putting a smaller ring connector underneath the big cables reduces the surface contact area which creates a poor connection that could generate heat under high current. On the fuse put the cable to Solenoid first, then the charging wire then any other smaller wires. |
|
10-15-2019, 12:19 PM | #10 | |
Not Yet Wild
Join Date: Jun 2016
Location: D/FW
Posts: 20
|
Re: No Power When Key Switch Turned On
Quote:
|
|
Tags |
alltrax 48400, series cart, txt, upgrade controller |
|
Thread Tools | |
Display Modes | |
|
Similar Threads | ||||
Thread | Forum | |||
starter keeps on running after key switch turned off | Gas EZGO | |||
Can't get power to key switch | Electric EZGO | |||
DPI,Should I switch Power Off While Not In Use? | Electric EZGO | |||
No power with switch on | Electric EZGO | |||
Rear lights stay on after switch turned off. | Electric Club Car |