Electric EZGO Electric EZ GO Marathon, Medalist, TXT and RXV. |
|
Thread Tools | Display Modes |
10-02-2013, 03:07 PM | #1 |
Gone Wild
Join Date: Jun 2013
Location: Atlanta Ga
Posts: 211
|
quick question
If I double up 6 gauge cables from f n r to motor will that help at all
|
Today | |
Sponsored Links
__________________
This advertising will not be shown in this way to registered members. Register your free account today and become a member on Buggies Gone Wild Golf Cart Forum |
|
10-02-2013, 03:14 PM | #2 |
Gone Mad
Join Date: Oct 2009
Location: Buford, GA
Posts: 8,988
|
Re: quick question
Quick answer, not much. I'm assuming a series motor?
While most folks will tell you a chain is only as strong as its weakest link, that ain't 100% true. However, in a series circuit, ALL "links" should be the same size, including battery interconnects. |
10-02-2013, 03:25 PM | #3 |
Gone Mad
Join Date: Oct 2009
Location: Buford, GA
Posts: 8,988
|
Re: quick question
Long answer: Weakest link in the chain. In a series circuit, we ain't really talking about failure modes are we?
Assumption: All cables are good. 25 feet of cables are 6 gauge. You have x Watts of heat dissipated due to resistance. Let's replace half of that with 2 gauge cables. In a series circuit, are we not more efficient now? DISCLAIMER:... |
10-02-2013, 03:36 PM | #4 |
Gone Mad
Join Date: Oct 2009
Location: Buford, GA
Posts: 8,988
|
Re: quick question
If I had a series buggy with 25 feet of 6 gauge cables, and I just happened to have 8 or 10 feet of cable to double up, with no more money to invest, I would do it. It ain't ideal, but it won't hurt.
|
10-02-2013, 03:46 PM | #5 |
Gone Wild
Join Date: Jun 2013
Location: Atlanta Ga
Posts: 211
|
Re: quick question
Thanks for responces I am just useing old part to build a shop buggy it is 02 fleet 650 amp controler and stock motor till it dies it is 36 volts at the moment
|
10-02-2013, 03:48 PM | #6 |
Gone Mad
Join Date: Oct 2009
Location: Buford, GA
Posts: 8,988
|
Re: quick question
The more amps, the greater the increase.
|
10-02-2013, 03:56 PM | #7 |
Gone Wild
Join Date: Jun 2013
Location: Atlanta Ga
Posts: 211
|
Re: quick question
Trying to get boss to let me put d+d torque motor on and big cables but don't want to put money in cart at my limit right now with hd noid
|
10-02-2013, 04:06 PM | #8 |
Gone Mad
Join Date: Oct 2009
Location: Buford, GA
Posts: 8,988
|
Re: quick question
Do it piece-meal. I'm a reformed government employee, and know how budgets work. "Solenoid failed. Now the motor failed. Now the cables failed. Now..."
|
10-02-2013, 05:05 PM | #9 |
Gone Wild
Join Date: Jun 2013
Location: Atlanta Ga
Posts: 211
|
Re: quick question
The double cables helped a bunch now all is cool to touch it will almost pull front end off ground with stock motor need to go burn it up so I can do the torque motor
|
10-02-2013, 07:36 PM | #10 |
Gone Mad
Join Date: Oct 2009
Location: Buford, GA
Posts: 8,988
|
Re: quick question
|
|
|
Similar Threads | ||||
Thread | Forum | |||
Quick Oil Question? | Gas Club Car | |||
Quick Question | Electric Club Car | |||
quick question | Gas Harley Davidson | |||
just a quick question | Electric Club Car | |||
Quick Question | Gas Yamaha |