04-03-2011, 11:23 AM | #1 |
Not Yet Wild
Join Date: Mar 2011
Location: Melbourne, Florida, USA
Posts: 4
|
2000 carryall 2 fuel gauge
Hi Folks!
In here working on a sunday, cause thats the only time all the carts are in the barn. Have a 2000 carryall2 with a bad fuel gauge. Got what I *think* is the correct replacement (103348601) but the terminal #3 is missing. (OK, looking while composing this- may be wrong gauge. Finding 101990701 listed for an 01-03, and it has the correct terminals.) Can I make the gauges I have work easily? Terminal 3 appears to be chassis ground. I am going to continue research, and will post if I find a solution. OK, last addition before posting. Looking at the wiring for an 08, and it shows connectors 1,2,3 and 4 being used. The part# fits an 08. The part has 1,2,4,6 and 7 labeled. Maybe I got the wrong part shipped. It is a SenDEC 0846. (other #s include 811ni720-ag0111r v5.0 25ma) EDIT- Turns out it is a SenDEC 811, the NI7 20 after that specs out the particulars for that gauge such as voltage, etc. Thanks! I am back out in the bay, but will check for replies frequently. Last edited by volkemon; 04-03-2011 at 11:51 AM.. Reason: Correct SenDEC part # figured out :) |
Today | |
Sponsored Links
__________________
This advertising will not be shown in this way to registered members. Register your free account today and become a member on Buggies Gone Wild Golf Cart Forum |
|
04-03-2011, 11:31 AM | #2 |
just leave me alone
Join Date: Aug 2008
Location: Tennessee
Posts: 5,643
|
Re: 2000 carryall 2 fuel gauge
If the mounting frame( metel) around the gage is grounded U may not need the seperate ground ?
|
04-03-2011, 11:33 AM | #3 |
Gone Wild
Join Date: Jul 2008
Location: Reddick IL
Posts: 11,220
|
Re: 2000 carryall 2 fuel gauge
Not sure but is three maybe for a gauge light???
|
04-03-2011, 11:46 AM | #4 |
Not Yet Wild
Join Date: Mar 2011
Location: Melbourne, Florida, USA
Posts: 4
|
Re: 2000 carryall 2 fuel gauge
Searched SenDEC 811 and it helped.
http://www.generatorsolutions.us/811...l%20Gauge.html I made this up from their picture. Feul gauge worked! I have to make a couple jumpers, but I suspect the hour meter will work also. EDIT! New picture. If the pins 2 and 7 are ganged together, the hour meter will run all the time the key is on, and ours are pedal start, so keys are on all weekend sometimes. Pin 2 comes from the IGN switch to run the feul meter, and pin 7 is now attached to the white wire on the starter/generator to give an accurate count of engine run time. Last edited by volkemon; 04-03-2011 at 12:17 PM.. Reason: added link, corrected diagram |
04-03-2011, 05:23 PM | #5 |
just leave me alone
Join Date: Aug 2008
Location: Tennessee
Posts: 5,643
|
Re: 2000 carryall 2 fuel gauge
pretty slick to have a dual function on 1 read out , R they expensive ?
|
|
|