problem solved:
Finally I was able to connect the accelerator hall and works perfect. This will supply voltage with +5 v (pin 26) and gnd (pin7) and the output signal (pin 16).
I've set the type 2 for 0-5V voltage source and then calibrate it with:
Forward Deadband, Forward Map, Forward Max y Forward Offset
I had the accelerator hall well connected but I was alarm the problem was that was turned on to "1" the protection HPD / SRO, disconnect and set to 0:
HPD / SRO Type 0-3 Determines the type of HPD / SRO protection. One type of checks is available for materials-handling vehicles, and two types for golf-style vehicles.
If any of the HPD / SRO checks finds an input sequencing problem, and HPD / Sequencing Fault (flash code 47) is set.