Battery to solenoid voltages (2002 CC Gas)
List of SOLENOID POLE symbols :
_1 - (#18 Orange) to Limit Switches
_2 - (#18 Blue) to Key
_3 - (#6 Red) to BAT (+) [also #18 Red to FUSE]
_4 - (#6 White) to GEN [also #18 red to VOLTAGE REGULATOR]
List of VOLTAGE readings across SOLENOID POLES:
POLES.............SYS-ON.................SYS-OFF
_1-2.................12.2........................0.0
_1-3.................12.5......................12.8
_1-4.................12.1........................0.0
_2-3...................0.0......................12.6
_2-4...................0.0........................0.0
_3-4...................0.0......................12.7
Line VOLTAGES from SOLENOID POLES to TERMINALS of the battery (SYS-ON):
POLE.............BAT (-).................BAT (+)
_1..................0.0.......................12.4
_2................12.2.........................0.0
_3................12.4.........................0.0
_4................12.3.........................0.0
In RUN MODE, key ON, F/R in F, wheels chocked, it seems that the solenoid is good. Still no ignition of the generator.
Going back to supply power to F1 on GENERATOR with jumper cables.
DANG IT'S HOT OUTSIDE!!!!
UPDATE: Power direct from BAT(+) to F1 = NEGATIVE ACTIVITY (no start/clicks/sound). I even turned the generator belt a twirl or two.
What next???
|