View Single Post
Old 12-04-2021, 02:44 PM   #4
DaveTM
Gone Wild
 
DaveTM's Avatar
 
Join Date: Oct 2012
Location: Southwestern Pa.
Posts: 6,215
Default Re: HV relay kicked in on the last two charges. Hmmm

Quote:
Originally Posted by Volt_Ampere View Post
Looks pretty good to me. Your max imbalance at high state of charge is 13mV which is decent. No cells are near their max of 4.2V.
I agree. But this is the first time an overcharge has occurred.....and twice in a row.

I think that since my HV cutoff is set at 4.01, Oh.....in typing this post I think I just figured out my screw up.

I have my MAX PER CELL set at 4.01.....when it should be 4.10!!!

I hate when that happens.

DaveTM is offline   Reply With Quote