Quote:
Originally Posted by Volt_Ampere View Post
S1 and S2 in a Series motor are in Series with the A1, A2 (Armature) The field is a very low resistance. Usually a Sepex motor has the field labeled F1, F2. Which motor do you have?
The field winding terminals on the SepEx motors used in DCS carts were labeled S1 & S2, which probably caused mixed marriages between Series and SepEx motors and controllers, so they were labeled F1 & F2 on the SepEx motors used in PDS carts.

The title of the thread states he has a 96 TXT DCS with an Alltrax controller, so his DCS motor is very likely labeled S1 & S2.
JohnnieB is offline   Reply With Quote