Re: New coil
Testing the Ignition Coil
Set the meter to the ohms scale, measure the resistance
between both primary wire terminals and between
the secondary wires (Ref Fig. 3 on page M-5). A normal
reading would be: Primary (+ and -): 1.87 - 2.53 W and
Secondary (A and B): 10.8 - 14.6KΩ. If readings
obtained are out of the above ranges, replace ignition coil
|