Default Re: LiFePO4 Converted Stock Yamaha - "Cold Start" Tripping of BMS

You can measure the voltage on the two sides of the solenoid to see if there is a precharge resistor. It can be internal to the controller. The Alltrax I have on my YDRE has an internal precharge resistor so you don't need one on the solenoid.