View Single Post
Old 03-11-2013, 03:48 PM   #16
plivanec
Not Yet Wild
Club Car
 
Join Date: Nov 2012
Location: Houston, Texas
Posts: 46
Default Re: 1999 CC regen 2 solenoids and coils

Quote:
Originally Posted by TahoeDawgZ71 View Post
Try the procedure. I just looked at a diagram and I see no reason it shouldn't work. As for the grey wire. Cut it off flush with the back of the receptacle. It's a sense lead wire that the OBC uses to communicate with the charger. You won't need it anymore. Sorry it took me so long to reply. Been sick with the flu and haven't been working.
I tried the procedure and it would not work. It did allow the charger to chare correctly, but the controller was constantly on. Even whith the tow/run switch in tow, it was still on. For some reason it got constant power. I put the OBC back in place and re-worked the grounding to the charger recepticle and the battery pack and got the charger to work properly. The issue I am now having is that I have no reverse. Forward works just fine, just no reverse. Any ideas as to what could cause this one? Everything was working just fine before...
plivanec is offline   Reply With Quote