***UPDATE***
Issue has been resolved, just as I was suspecting after troubleshooting the
Starter generator was internally shorting the field coil wire to the case which
Which was causing both F terminals and DF terminal to constantly show
Continuity to the case- looked like the manufacturer knew about it and tried to
Fix it with some insulator paper but it had shifted- I moved the wire from touching the housing and wrapped with insulator and sure enough all three terminals were good- re assembled and installed on cart and sure enough the voltage is 12.7 resting and 14.6 charging at high rpm’s - highly recommend bench testing any admiral MOT-2003 starter generators before you leave the Supplier - most won’t warranty, they are very expensive, and I had two consecutive parts that were both crap with separate issues -
|