Default Re: G1 Charging ? How to Test?

Quote:
Originally Posted by scottyb View Post
Set the digital voltmeter to 20VDC & check the battery state of charge voltage before the test. ie: 12.84 v or whatever. Then start the motor and recheck battery voltage with the motor running above idle speed. Voltage will increase with generator working.
Like Scotty said......You should read 14.5 to 15.5 volts as rpms encrease. Your stock Yamaha voltage regulator is adjustable. Take the cap off, the is a screw and jam nut...loosen jam nut and turn screw in (to increase) or out. Make shure you put the cap on and recheck voltage readings, they can change.