03-30-2019, 06:46 PM | #11 |
MOD of all BS!
Join Date: Sep 2011
Location: Florida
Posts: 17,477
|
Re: Charging issue
You can bypass the OBC by running a jumper from the back side of the charge receptacle (where the black 10g wire is that goes into the harness) and run it directly to the Main Pack Negative. Also take the grey sense wire coming off the same receptacle and land it to the same place. This will allow the charger to turn on "if" the OBC has failed. Note- This is only to test and not to make normal operation.
|
|
|